smartctl 6.6 2017-11-05 r4594 [x86_64-linux-4.19.0-10-amd64] (local build) Copyright (C) 2002-17, Bruce Allen, Christian Franke, www.smartmontools.org === START OF INFORMATION SECTION === Device Model: SSDSC2KB019T8R Serial Number: PHYF917601PP1P9DGN LU WWN Device Id: 5 5cd2e4 150dbd9dd Add. Product Id: DELL(tm) Firmware Version: XCV1DL63 User Capacity: 1,920,383,410,176 bytes [1.92 TB] Sector Sizes: 512 bytes logical, 4096 bytes physical Rotation Rate: Solid State Device Form Factor: 2.5 inches Device is: Not in smartctl database [for details use: -P showall] ATA Version is: ACS-3 T13/2161-D revision 5 SATA Version is: SATA 3.2, 6.0 Gb/s (current: 6.0 Gb/s) Local Time is: Fri Feb 19 08:51:24 2021 UTC SMART support is: Available - device has SMART capability. SMART support is: Enabled === START OF READ SMART DATA SECTION === SMART Status not supported: ATA return descriptor not supported by controller firmware SMART overall-health self-assessment test result: PASSED Warning: This result is based on an Attribute check. General SMART Values: Offline data collection status: (0x00) Offline data collection activity was never started. Auto Offline Data Collection: Disabled. Self-test execution status: ( 0) The previous self-test routine completed without error or no self-test has ever been run. Total time to complete Offline data collection: ( 0) seconds. Offline data collection capabilities: (0x79) SMART execute Offline immediate. No Auto Offline data collection support. Suspend Offline collection upon new command. Offline surface scan supported. Self-test supported. Conveyance Self-test supported. Selective Self-test supported. SMART capabilities: (0x0003) Saves SMART data before entering power-saving mode. Supports SMART auto save timer. Error logging capability: (0x01) Error logging supported. General Purpose Logging supported. Short self-test routine recommended polling time: ( 1) minutes. Extended self-test routine recommended polling time: ( 60) minutes. Conveyance self-test routine recommended polling time: ( 60) minutes. SCT capabilities: (0x003d) SCT Status supported. SCT Error Recovery Control supported. SCT Feature Control supported. SCT Data Table supported. SMART Attributes Data Structure revision number: 1 Vendor Specific SMART Attributes with Thresholds: ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE 1 Raw_Read_Error_Rate 0x000e 130 130 039 Old_age Always - 4294967295 5 Reallocated_Sector_Ct 0x0033 100 100 001 Pre-fail Always - 0 9 Power_On_Hours 0x0032 100 100 000 Old_age Always - 13522 12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always - 27 13 Read_Soft_Error_Rate 0x001e 088 088 000 Old_age Always - 281474976710655 170 Unknown_Attribute 0x0033 100 100 010 Pre-fail Always - 0 174 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 25 179 Used_Rsvd_Blk_Cnt_Tot 0x0033 100 100 010 Pre-fail Always - 0 180 Unused_Rsvd_Blk_Cnt_Tot 0x0032 100 100 000 Old_age Always - 14741 181 Program_Fail_Cnt_Total 0x003a 100 100 000 Old_age Always - 0 182 Erase_Fail_Count_Total 0x003a 100 100 000 Old_age Always - 0 184 End-to-End_Error 0x0032 100 100 000 Old_age Always - 0 194 Temperature_Celsius 0x0022 100 100 000 Old_age Always - 24 195 Hardware_ECC_Recovered 0x0032 100 100 000 Old_age Always - 0 197 Current_Pending_Sector 0x0012 100 100 000 Old_age Always - 0 198 Offline_Uncorrectable 0x0010 100 100 000 Old_age Offline - 0 199 UDMA_CRC_Error_Count 0x003e 100 100 000 Old_age Always - 16514 201 Unknown_SSD_Attribute 0x0033 100 100 010 Pre-fail Always - 120259021426 202 Unknown_SSD_Attribute 0x0027 100 100 000 Pre-fail Always - 0 225 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 1167544 226 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 389 227 Unknown_SSD_Attribute 0x0032 100 100 000 Old_age Always - 59 228 Power-off_Retract_Count 0x0032 100 100 000 Old_age Always - 811163 232 Available_Reservd_Space 0x0033 100 100 010 Pre-fail Always - 0 233 Media_Wearout_Indicator 0x0032 100 100 000 Old_age Always - 1167544 234 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 0 241 Total_LBAs_Written 0x0032 100 100 000 Old_age Always - 1167544 242 Total_LBAs_Read 0x0032 100 100 000 Old_age Always - 1731053 245 Unknown_Attribute 0x0032 100 100 000 Old_age Always - 100 SMART Error Log not supported SMART Self-test log structure revision number 1 No self-tests have been logged. [To run self-tests, use: smartctl -t] Read SMART Selective Self-test Log failed: megasas_cmd result: 0.1 = 0/45