Adapter 0 -- Virtual Drive Information: Virtual Drive: 0 (Target Id: 0) Name : RAID Level : Primary-1, Secondary-0, RAID Level Qualifier-0 Size : 232.375 GB Sector Size : 512 Mirror Data : 232.375 GB State : Optimal Strip Size : 64 KB Number Of Drives : 2 Span Depth : 1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: No LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: Yes Cache Cade Type : Read Only Virtual Drive: 1 (Target Id: 1) Name : RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0 Size : 3.637 TB Sector Size : 512 Parity Size : 0 State : Optimal Strip Size : 64 KB Number Of Drives : 1 Span Depth : 1 Default Cache Policy: WriteBack, ReadAhead, Direct, Write Cache OK if Bad BBU Current Cache Policy: WriteBack, ReadAhead, Direct, Write Cache OK if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: Yes LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: Yes Cache Cade Type : Read Only Virtual Drive: 2 (Target Id: 2) Name : RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0 Size : 3.637 TB Sector Size : 512 Parity Size : 0 State : Optimal Strip Size : 64 KB Number Of Drives : 1 Span Depth : 1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: No LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: Yes Cache Cade Type : Read Only Virtual Drive: 4 (Target Id: 4) Name : RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0 Size : 3.637 TB Sector Size : 512 Parity Size : 0 State : Offline Strip Size : 64 KB Number Of Drives : 1 Span Depth : 1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: No LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: Yes Is VD Cached: Yes Cache Cade Type : Read Only Virtual Drive: 5 (Target Id: 5) Name : RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0 Size : 3.637 TB Sector Size : 512 Parity Size : 0 State : Optimal Strip Size : 64 KB Number Of Drives : 1 Span Depth : 1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: No LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: Yes Cache Cade Type : Read Only Virtual Drive: 6 (Target Id: 6) Name : RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0 Size : 3.637 TB Sector Size : 512 Parity Size : 0 State : Optimal Strip Size : 64 KB Number Of Drives : 1 Span Depth : 1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: No LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: Yes Is VD Cached: Yes Cache Cade Type : Read Only Virtual Drive: 8 (Target Id: 8) Name : RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0 Size : 3.637 TB Sector Size : 512 Parity Size : 0 State : Optimal Strip Size : 64 KB Number Of Drives : 1 Span Depth : 1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: No LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: Yes Cache Cade Type : Read Only Virtual Drive: 10 (Target Id: 10) Name : RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0 Size : 3.637 TB Sector Size : 512 Parity Size : 0 State : Optimal Strip Size : 64 KB Number Of Drives : 1 Span Depth : 1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: No LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: Yes Cache Cade Type : Read Only Virtual Drive: 11 (Target Id: 11) Name : RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0 Size : 3.637 TB Sector Size : 512 Parity Size : 0 State : Optimal Strip Size : 64 KB Number Of Drives : 1 Span Depth : 1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: No LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: Yes Cache Cade Type : Read Only Virtual Drive: 12 (Target Id: 12) Name : RAID Level : Primary-0, Secondary-0, RAID Level Qualifier-0 Size : 3.637 TB Sector Size : 512 Parity Size : 0 State : Optimal Strip Size : 64 KB Number Of Drives : 1 Span Depth : 1 Default Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Current Cache Policy: WriteBack, ReadAdaptive, Direct, No Write Cache if Bad BBU Default Access Policy: Read/Write Current Access Policy: Read/Write Disk Cache Policy : Disk's Default Encryption Type : None Default Power Savings Policy: Controller Defined Current Power Savings Policy: None Can spin up in 1 minute: Yes LD has drives that support T10 power conditions: No LD's IO profile supports MAX power savings with cached writes: No Bad Blocks Exist: No Is VD Cached: Yes Cache Cade Type : Read Only Exit Code: 0x00